High resolution spectrometer
High resolution spectrometer
High resolution spectrometer HR4000
Description
The Ocean Optics HR4000 Spectrometer includes the linear CCD-array optical bench, plus all the circuits necessary for spectrometer operation. The result is a compact, flexible system, with no moving parts, that's easily integrated as an OEM component.
The HR4000 spectrometer is a unique combination of technologies providing users with both an unusually high spectral response and high optical resolution in a single package. The electronics have been designed for considerable flexibility in connecting to various modules as well as external interfaces. The HR4000 interfaces to PC’s, PLC’s and other embedded controllers through USB 2.0 or RS-232 communications. The information included in this guide provides detailed instructions on the connection and operation of the HR4000.
The detector used in the HR4000 spectrometer is a high-sensitivity 3648-element CCD array from Toshiba, product number TCD1304AP. Ocean Optics applies a coating to all TCD1304AP detectors, so the optical sensitivity could vary from that specified in the Toshiba datasheet).
The HR4000 operates off of a single +5VDC supply and either a USB or RS-232 interface. The HR4000 is a microcontroller-controlled spectrometer, thus all operating parameters are implemented through software interfacing to the unit.
Features:
q TCD1304AP Detector
High sensitivity detector
Readout Rate: 1MHz
Shutter mode
q Optics
An optical resolution of ~0.03nm (FWHM)
A wide variety of optics available
14 gratings
6 slit widths
1 order sorting filter
q Electrical Performance
14 bit, 5MHz A/D Converter
Integration times from 3.8ms to 10s
q 4 triggering modes
q Embedded microcontroller allows programmatic control of all operating parameters & Standalone operation
USB 2.0 480Mbps (High Speed) & 12Mbps (Full speed)
RS232 115Kbaud
Multiple Communication Standards for digital accessories (SPI, I2C)
q Onboard Pulse Generator
2 programmable strobe signals for triggering other devices
Software control of nearly all pulse parameters
q Onboard GPIO
10 user programmable digital I/O
q Onboard Analog Interface
Analog Output: 9bit, 0-5V
q EEPROM storage for
Wavelength Calibration Coefficients
Linearity Correction Coefficients
Absolute Irradiance Calibration (optional)
q Plug-n-Play Interface for PC applications
q 30-pin connector for interfacing to external products
q CE Certification
Specifications
|
Specifications |
Criteria |
|
Absolute Maximum Ratings: VCC Voltage on any pin |
+ 5.5 VDC Vcc |
|
Physical Specifications: Physical Dimensions Weight |
148.6 mm x 104.8 mm x 45.1 mm 570 g |
|
Power: Power requirement (master) Supply voltage Power-up time |
500 mA at +5 VDC 4.5 – 5.5 V ~5s depending on code size |
|
Spectrometer: Design Focal length (input) Focal length (output) Input Fiber Connector Gratings Entrance Slit Detector Filters |
Asymmetric crossed Czerny-Turner F/4 101mm 68 mm (75, 83 and 90 mm focal lengths also available) SMA 905 to single-strand optical fiber (0.22 NA) 14 different gratings 5, 10, 25, 50, 100, or 200 μm slits. (Slits are optional. In the absence of a slit, the fiber acts as the entrance slit.) Toshiba TCD1304AP 2nd & 3rd order rejection, long pass (optional) |
|
Spectroscopic: Integration Time Dynamic Range Signal-to-Noise Readout Noise (single dark spectrum) Resolution Spectrometer Channels |
3.8 ms – 10sec 2500 single integration period, 2.5 x 109 over integration range 300:1 single acquisition 6 counts RMS, 20 counts peak-to-peak 0.03 – 1.0 nm varies by configuration One |
|
Environmental Conditions: Temperature Humidity |
-30 to +70 C Storage & -10 to +50 C Operation 0% - 90% non-condensing |
|
Interfaces: USB RS-232 I2C |
USB 2.0, 480 Mbps 2-wire RS-232 Inter-Integrated Circuit 2-Wire serial BUS |