4 Port Polarization Maintaining Optical Circulator
4 Port Polarization Maintaining Optical Circulator
4 Port Polarization Maintaining Optical Circulator
4 Port Polarization Maintaining Optical Circulator
Features |
|
Low Insertion Loss High Extinction Ratio & High Isolation High stability and reliability |
|
Application |
|
EDFA Fiber Optical Instrument Fiber Sensor Fiber sensor |
Type Parameter |
Type A |
Type B |
Type B |
Operating wavelength (nm) |
1310 or 1550 |
1064 |
|
Bandwidth |
±30 |
±20 |
±5 |
Typ. Isolation 23℃(dB) |
50 |
30 |
35 |
Isolation 23℃(dB) |
≥40 |
≥20 |
≥28 |
Typ. Insertion Loss 23℃ (dB) |
0.8 |
0.7 |
2.1 |
Insertion Loss (dB) |
≤1.1 |
≤1.0 |
≤2.8 |
Extinction Ratio (dB) |
≥20 |
≥20 |
≥20 |
Cross Talk (dB) |
≥50 |
||
Return loss (dB) |
≥50 |
||
Power handling (CW, total) (mW) |
≤300 |
||
Fiber Type |
Panda Fiber |
||
Operating temperature (℃) |
-5 ~ +70 |
-5 ~ +50 |
|
Storage temperature (℃) |
-40 ~ +85 |
||
Dimensions (mm) |
φ5.5×L35 |
*Above specifications are for devices without the connectors.
*For devices with connectors, IL will be 0.3dB higher, RL will be 5dB lower, and ER will be 2dB lower. *The PM fiber and the connector key are aligned to the slow axis. And for F type, fast axis is blocked.
*The transmission optical path of A type is different from B type:Type A: 1 -> 2, 2 -> 3, 3 -> 4; Type B: 1 -> 2, 2 -> 3, 3 -> 4;4->1
Ordering Information
PMCIR |
Port |
Type |
Wavelength |
Axis Alignment |
Pigtail Type |
Fiber Type |
Length |
Connector |
|
4=4 Port |
A B |
1064 1310 1550 |
F=Fast axis blocked |
250=250um bare fiber 900=900um loose tube 3000=3mm loose tube |
5=Panda fiber |
0.8= 0.8m 1=1m |
NE=None FA=FC/APC FC=FC/UPC SA=SC/APC SC=SC/UPC XX=Other |